RADPAD® Radiation Protection

Advanced Scatter Radiation Protection for Interventional Environments

  • Up to 95%* reduction in scatter radiation
  • Lead-free and environmentally friendly
  • Sterile, disposable and easy to use
  • Supports ALARA principles
  • Designed to integrate seamlessly into existing workflows
Our white paper explores the potential long-term effects
of low-level X-ray radiation exposure on healthcare professionals, including the links between chronic inflammation and cardiovascular disease, metabolic dysfunction, cognitive impairment and cancer.
RADPAD® can provide an additional layer of protection
against scatter radiation, complementing existing radiation
safety measures.

Please see our radiation protection website for more information.

RADPAD® Disposable Radiation Shields (5000 Series)

RADPAD® Disposable Radiation Shields are sterile, lead-free, lightweight, and disposable radiation protection shields placed directly over sterile patient drapes. They provide physicians with protection from scatter radiation during interventional procedures. First developed in 1996 as a lightweight pliable alternative to lead shielding, RADPAD® shields have been tested in numerous independent studies and proven to be effective in reducing scatter radiation in multiple medical interventional specialities utilising x-radiation.

Key features

  • Simple one-time use shields positioned over the sterile drape
  • Protects physician and scrub nurse against scatter radiation
  • Lead-free for easy disposal after the case
  • Intelligently shaped for each procedure to give maximum protection
  • Sterile and disposable
  • Multiple attenuation levels: Red (95%*), Orange (90%), Yellow (75%)
Shield Configurations
  • Interventional Shield Radial (12×16 inch) – Optimised for radial access
  • Peripheral Shield (11×34 inch) – Extended coverage for peripheral interventions
  • Biopsy Shield (12×16 inch) – Image-guided biopsy procedures
  • Femoral Entry Angiography Shield (16×14 inch) – Femoral access protection
  • Jugular Access/TIPS Shield (12×16 inch) – Transjugular procedures
  • EP Left Subclavian Shield (12×16 inch) – EP device implantation
  • Biliary Shield (12×16 inch) – Biliary drainage and intervention
  • Fenestrated Radial Entry Shield (14×16 inch) – Strategic access and protection

Case quantity: 15 units

RADPAD® No-Brainer® Cap (9100 Series)

The RADPAD® No-Brainer® is lightweight, disposable, and lead-free radiation protection for the head. Designed to protect interventional staff during fluoroscopy-guided procedures, the cap addresses an area that remains unprotected even when wearing lead aprons, thyroid collars, and protective eyewear.

Key features

  • Lightweight and disposable

  • Lead-free construction for environmentally safe disposal

  • Attenuates scatter radiation, blocking up to 95%* at 90kVp

  • Unique composite material

Case quantity: 20 units

RADPAD® 9700 Series Table Skirts with Anchor

RADPAD® Table Skirts provide fixed protection at the source, preventing scatter radiation from escaping beneath the procedure table. Rather than relying solely on personal protective equipment, these table-mounted shields address radiation before it reaches clinical staff, delivering over 80% protection to the operator’s lower body and pelvis.

Key features

  • Over 80% radiation protection by keeping radiation under the table
  • Prevents radiation escaping at tabletop edge or between slits
  • Secure anchor system for stable positioning
  • Clinically proven effectiveness at all table angles (0°, 15°, 30°, 45° oblique)
  • Lead-free construction
  • Custom configurations for different table types

RADPAD® Shield Caddy (9200 Series)

The RADPAD® Shield Caddy provides organised, hygienic storage for disposable radiation protection shields within clinical environments. Purpose-designed to maintain shield integrity and accessibility, this storage solution supports efficient workflow in busy interventional suites.

Key features

  • Dedicated storage for RADPAD® shields

  • Maintains organisation and accessibility

  • Protects product integrity

  • Compact footprint suitable for catheterisation laboratories

  • Durable construction

  • Available in blue

Proper shield storage ensures rapid access during time-sensitive procedures, reduces risk of product damage, and eliminates the need for makeshift storage solutions. The Shield Caddy supports well-organised, efficient clinical environments.

RADPAD® 9720 Series Gantry Shield

The RADPAD® Gantry Shield provides mobile radiation protection for personnel working with C-arm fluoroscopy units or near CT scanners. This fully mobile shield system can be positioned where needed, then stored compactly when not in use.

Key features

  • Expandable design: adjusts from 36″ to 52″ in height (91.4cm to 132cm)
  • 48″ wide (121.9cm)
  • Folds to 5″ deep (12.7cm) for easy storage
  • Locking wheels for secure positioning during procedures
  • Easy mobility – can be repositioned throughout the room
  • Durable stand with locking mechanisms
  • Lead-free construction
*Dependent on product selection and positioning
Radpad Trademark owned by Worldwide Innovations & Technologies (WIT), Missouri, US

Resources

Radiation Protection Guidance

Whitepaper

Flyer